Stock code:600312      |                         |         

Copyright ® Henan pinggao Electric Co.,Ltd         豫ICP备05010380号

Service

Company name: henan pinggao electric co. LTD

Address: Henan province of pingdingshan city

south ring road 22

Mail editor: 467000
E -  mail : pinggao@pinggao.esgcc.com.cn

400-6700-312

If you need to consult other business, you can call the hotline directly.

General department: +86-375-3804029

Securities department: +86-375-3804064

Sales: +86-375-3803888

Customer service center: 400-6700-312

PRODUCT

>
Products_detail

PRODUCTS

JW5-1100/J63 type Disconnector

Description

JW5-1100/J63 type Disconnector

JW5-1100/J63 high voltage earthing switch adopts folding plug-in structure, can effectively reduce the area and reduce the cost of power station construction, uses the counter weight and balance spring together to balance the change of potential energy, flexible and convenient operation, stable and reliable opening and closing process. When the closing is finished, the support rod and grounding arbor constitute a triangular frame structure, after the closing, the product has a higher stiffness and stability. Rated short-time withstand current 63kA(3s), mechanical life 5000 times, the technical performance is stale and reliable. This product has been passed the national identification in July 2010 which was organized by China Machinery Industry Federation, its technical performance reached the international advanced level.

1.Products meet the following standards and technical conditions

GB 1985-2004 High-voltage alternating-current disconnectors and earthing switches

GB/T 191-2008 packaging-pictorial marking for handling of goods

GB/T 4585-2004 Artifitial pollution tests on high-voltage insulators to be used on a.c. systems

GB/T 11022-1999 Common specifications for high-voltage switchgear and controlgear standards

GB/T 13540-2009 Seismic qualification for high-voltage switchgear and controlgear

GB/T 20635-2006 Special environment condition Technical requirements for high-voltage apparatuses for plateau

DL/T 486-2000 Specifications for HV AC disconnectors and earthing switches

DL/T 593-2006 Common specifications for high-voltage switchgear and controlgear standards

2. Service environment

2.1 The surrounding air temperature: -40℃~+40℃

2.2 Altitude: ≤1000m

2.3 Wind speed: ≤34m/s

2.4 Icing-thickness: ≤10mm

2.5 outer-insulation pollution class

2.6 seismic intensity: ≤ 9°

2.7 The installation site should be free of severe vibration and flammable, explosive materials and chemical corrosion.

3. The main technical parameters

 

Specifications

Unit

Value

Rated voltage

kV

1100

Rated short-time withstand current

kA

63

 rated duration of short-circuit

S

3

Rated peak withstand current

kA

170

Rated short-time power frequency withstand voltage(effective value)

kV

1100

Rated lightning impulse withstand voltage(peak1.2/50μs)

kV

2400

Rated operating impulse withstand voltage(peak250/2500μs)

kV

1800

Rated terminal static mechanical load

N

Longitudinal 4000
Horizontal 3000
Vertical 2000